fluke 87 meter manual

Fluke 87 Series Overview

The Fluke 87 Series delivers true‑RMS accuracy for AC/DC voltage and current. It features a 10‑digit display‚ auto‑range‚ and internal temperature compensation. Service manuals (PN 834192) detail calibration‚ sensor checks‚ and safety steps for reliable operation. Ideal for technicians and labs only

Key Features and Specifications

The Fluke 87 Series True RMS multimeter offers precise measurement across a broad range of electrical parameters. Key specifications include:

  • Voltage range: 200 V AC‚ 600 V DC‚ 2000 V AC‚ 2000 V DC
  • Current range: 10 A AC‚ 10 A DC‚ 100 mA AC‚ 100 mA DC
  • True RMS accuracy: ±0.05 % full scale for AC‚ ±0.05 % for DC
  • Auto‑range with 10‑digit display and 3‑digit decimal resolution
  • Internal temperature sensor for compensation and 30‑minute stabilization before calibration
  • Built‑in 1 kΩ‚ 100 kΩ‚ 10 MΩ‚ 1 MΩ‚ 10 kΩ‚ 100 Ω‚ and 10 Ω resistors for calibration
  • IR and serial communication ports for remote control and data logging
  • Safety features: CAT III (600 V)‚ CAT IV (600 V) compliance‚ overload protection‚ and auto‑shutdown
  • Serviceable with Fluke service manual PN 676137 and PN 834192 for calibration and part replacement

It supports both AC and DC measurement modes‚ with a 0.1 % resolution at full scale. Calibration is performed using the internal 1 kΩ reference resistor and external calibration sources‚ ensuring traceability to national standards. The meter’s rugged design includes a 2 mm thick protective case. 10 mm depth AC

Data logging can be enabled via the serial port‚ storing up to 10‚000 samples in internal memory. The device can be controlled remotely using the IR remote‚ allowing quick mode changes without manual interaction.

CE‑certified and meet IEC 61010 safety standards.

Initial Setup and Calibration

Before use‚ allow the meter to stabilize at ambient temperature for 30 min. Switch OFF‚ then ON. Connect the IR adapter to the PC’s serial port. Follow the calibration procedure in PN 834192‚ using the internal 1 kΩ reference resistor. Verify accuracy within ±0.05 %. Calibration verified by Fluke service.

Calibration Procedure and Requirements

Prior to calibration‚ ensure the Fluke 87 is powered off and has rested at ambient temperature for at least 30 minutes. The internal temperature sensor and input terminals must reach thermal equilibrium to avoid drift. Connect the IR adapter to the PC’s serial port and launch the Fluke Calibration Utility. Select the 87 series model and load the calibration file (PN 834192). The utility will guide you through a series of voltage and current reference steps: 0 V‚ 10 V‚ 100 V‚ 1 kV for AC and DC; 0 mA‚ 10 mA‚ 100 mA‚ 1 A for current. At each step‚ apply the reference source‚ wait for the display to stabilize‚ and record the reading. The meter’s internal 1 kΩ reference resistor is used to verify the accuracy of the voltage measurement. If the displayed value deviates beyond the specified tolerance (±0.05 % for voltage‚ ±0.1 % for current)‚ repeat the step or contact Fluke support. After completing all steps‚ the utility will calculate calibration coefficients and store them in the meter’s EEPROM. Verify the calibration by measuring a known reference and comparing the result to the expected value. Store the calibration log in the PC for future reference. Keep the meter’s firmware updated to the latest revision to ensure compatibility with the calibration software. For detailed troubleshooting‚ consult the Service Manual (PN 676137) and contact Fluke technical support if issues persist.

During calibration‚ maintain a stable power supply and avoid electromagnetic interference. Use shielded cables and ensure all connections are secure. The meter’s auto‑range feature should be disabled during the procedure to prevent unintended range changes. After calibration‚ perform a quick verification by measuring a known 50 Hz AC sine wave and a 60 Hz DC voltage. Document the results in the calibration log. If the meter passes all checks‚ it is ready for field use. Store the meter in a climate‑controlled environment to preserve calibration integrity. Periodic re‑calibration is recommended every 12 months or after any significant mechanical shock. The calibration process should be performed by a qualified technician with access to calibrated reference sources.

Measurement Functions and Modes

The Fluke 87 measures AC/DC voltage‚ AC/DC current‚ resistance‚ diode‚ continuity‚ and temperature. Auto‑range selects the best setting; true‑RMS ensures accurate AC readings. Use the rotary switch to select mode‚ and the display shows 10‑digit results. 2026!!

AC and DC Voltage and Current Measurements

The Fluke 87 Series True RMS multimeter offers precise AC and DC voltage and current measurement capabilities essential for professional electrical testing. Its 10‑digit display and auto‑range selector automatically adjust to input levels‚ ensuring optimal resolution across a wide range of signals. For AC voltage‚ the meter employs a true‑RMS algorithm that accurately captures non‑sinusoidal waveforms‚ providing reliable readings even in industrial environments with harmonic distortion. DC voltage measurements benefit from a low‑noise‚ high‑precision input stage that minimizes offset error‚ delivering ±0.02 % accuracy over the full range.

Current measurement is performed via a built‑in shunt resistor for DC current and a Hall‑effect sensor for AC current. The DC shunt provides 0.1 A to 10 A range with ±0.05 % accuracy‚ while the AC Hall sensor covers 0.1 A to 10 A with ±0.1 % precision. Both modes support true‑RMS detection‚ allowing accurate representation of AC currents with complex waveforms. The meter’s internal temperature compensation stabilizes the reference junction‚ reducing drift and maintaining accuracy within ±0.02 % over a 25 °C to 45 °C ambient range.

Calibration is performed using the Fluke 87 Service Manual (PN 676137) guidelines‚ which recommend a 30‑minute stabilization period at constant ambient temperature before initiating the procedure. The meter’s internal reference junction and input terminals must reach thermal equilibrium to ensure traceable accuracy. Users can verify calibration by shorting input leads in AC mode‚ where the meter should display a reading less than 25 digits‚ indicating minimal internal offset. The 87’s firmware also allows for serial communication via an IR adapter‚ enabling automated calibration checks and data logging for quality assurance.

Overall‚ the Fluke 87’s combination of true‑RMS processing‚ auto‑range selection‚ and rigorous calibration procedures makes it a reliable tool for measuring AC and DC voltage and current across a broad spectrum of industrial and laboratory applications. Its robust design and compliance with safety standards ensure consistent performance in demanding environments. In addition‚ the meter supports a 1 Hz to 10 kHz bandwidth for AC measurements‚ allowing accurate capture of high‑frequency signals commonly found in power electronics. The device’s rugged chassis and IP65 rating protect against dust and water ingress‚ making it suitable for field deployment. The user interface includes a backlit screen and programmable buttons that can be configured for frequently used functions‚ reducing setup time during testing tasks.

Safety Precautions and Compliance

The Fluke 87 meets IEC 61010‚ UL 61010‚ and CSA C22.1 standards. Use insulated tools‚ avoid touching live contacts and respect the 10 A current limit. Keep the meter dry‚ store in a cool dry place and adhere to all safety warnings. Follow the lockout tag saf!!

Electrical Safety Guidelines

Before using the Fluke 87‚ inspect the meter for physical damage‚ ensuring that the casing‚ buttons‚ and display are intact. Verify that all probe connectors are securely attached and that no insulation is cracked. Confirm that the device is powered from a stable‚ grounded supply; the meter’s internal fuse protects against overcurrent‚ but a faulty power source can still pose hazards. Do not exceed the maximum input ratings: 600 V AC/DC‚ 10 A AC‚ 10 A DC; exceeding these limits can damage the meter and create a fire risk. Keep the meter away from conductive surfaces‚ water‚ and other liquids; moisture can cause short circuits and electrical shock. When measuring high‑voltage circuits‚ first disconnect the power source and verify zero voltage with the meter set to the lowest range. Observe the 10 A current limit; for higher currents use a shunt or clamp meter instead of the Fluke 87. Never touch live terminals while the meter is powered; use insulated probes and gloves rated for the voltage level. Follow the manufacturer’s lock‑out/tag‑out procedures during maintenance or when changing batteries. In case of a fault or abnormal reading‚ immediately disconnect the power and contact Fluke support. Adhere to all local electrical codes and regulations; the Fluke 87 complies with IEC 61010‚ UL 61010‚ and CSA C22.1‚ ensuring safe operation when used correctly. Always read the full user manual before operating the instrument‚ and keep the safety information in a readily accessible location for all users. Always wear insulated gloves when handlinghigh voltage

Using the Remote Control Interface

The Fluke 87 supports remote control via IR and serial ports. Connect the IR adapter to the PC’s COM port‚ then use the included software to send commands. The meter accepts command strings for mode‚ range‚ and data retrieval‚ enabling automated logging. Use RS‑232 for scripted data logging USB!

IR and Serial Communication Setup

To enable remote control‚ attach the Fluke 87’s IR adapter to the PC’s serial COM port. The adapter uses a standard RS‑232 interface; ensure the cable’s DTR and RTS lines are enabled. Once connected‚ launch the Fluke 87 Remote Control software (included with service package PN 834192). The software detects the COM port and configures baud rate‚ data bits‚ parity‚ and stop bits to 9600 bps‚ 8‑N‑1. After establishing communication‚ the meter’s display shows “IR Connected” and the status LED flashes. The meter’s IR receiver is located on the front panel‚ and the adapter’s LED will illuminate when a command is received. The software’s status window displays the current mode and measurement value in real time.

To send commands‚ type the command string into the terminal window. For example‚ “V AC R 1” sets the meter to AC voltage‚ auto‑range‚ and 1‑second averaging. The meter replies with the reading in the format “+000.000 V”. Use “I DC R 0” for DC current‚ zero‑range. The command list is in the user manual; common commands include “S 1” to start data logging‚ “S 0” to stop‚ and “L ” to retrieve logged data. The meter also supports a continuous measurement mode‚ which can be activated with the command “C 1” to stream data to the PC.

When using the IR remote‚ press the “IR Setup” button to activate IR mode. Point the IR transmitter at the meter’s receiver‚ then send the same command strings via the PC. The meter echoes the command and returns the reading. For serial logging‚ connect the meter to a data acquisition system and configure it to output data at a fixed interval (e.g.‚ 1 Hz) using the “T ” command. The meter will then transmit readings continuously until the “T 0” command is issued. The serial interface supports both 9‑bit and 8‑bit data frames‚ allowing compatibility with legacy equipment.

Always verify the COM port settings before sending commands. If the meter does not respond‚ check the cable‚ ensure the meter’s power is on‚ and confirm that the IR adapter is properly seated. The Fluke 87’s remote interface allows automated test sequences‚ data logging‚ and integration with laboratory software‚ making it a versatile tool for precision measurements. For high‑speed logging‚ set the meter to 10 Hz by sending “T 10”; the meter will then send ten readings per second.

Data Logging and Memory Features

The Fluke 87 stores up to 1‚000 readings in internal memory. Use the “S 1” command to start logging‚ “S 0” to stop‚ and “L ” to retrieve data via the serial port. Data can be exported to a PC for analysis. Use “L 0” to download logs; Entry is timestamped.!!!

Cleared with “C M”.Logging 1‑second averaging.

Configuring Data Storage and Retrieval

To begin logging‚ press the LOG button until the display shows “S 1”. The meter will record each measurement into its 1‚000‑slot internal memory. Use the MODE button to cycle between AC‚ DC‚ and RESISTANCE logging. Each entry is timestamped with the last four digits of the current date and time.

When you wish to download the data‚ connect the serial port to a PC and launch Fluke’s Data Logger software. Select the device COM port‚ set 115200 bps‚ 8‑N‑1‚ and click CONNECT. The meter will respond to the L  command‚ which returns all stored entries. Use L 0 to retrieve the entire log‚ or L n to fetch the nth entry.

To clear memory‚ press CLR until the display shows “C M”. Confirm with YES. The meter will erase all stored data. Remember that logging can be paused with LOG 0 and resumed with LOG 1. For continuous logging‚ set the TIME interval to 1 second using the TIM menu. This ensures high‑resolution data capture for dynamic measurements.

Advanced users can configure the meter to store data to an external SD card by selecting MEM > EXT in the menu. The SD card must be formatted to FAT32. Once enabled‚ the meter will automatically write each logged entry to the card‚ allowing for larger storage capacity and easier data transfer.

Use the USB port to export the full log in CSV format. Connect a drive‚ then issue EXPORT to transfer data for analysis!!.

Maintenance and Service Instructions

Check probe tips‚ clean with isopropyl alcohol‚ and replace contactsif corroded.Verify the internal temperature sensor against a calibrated thermometer. Store the meter in a dry‚ temperature‑controlled environment to maintain accuracy for safety!.

Service Manual Reference and Parts Replacement

For detailed troubleshooting‚ calibration‚ and part identification‚ consult the Fluke 87 Service Manual (PN 834192‚ Rev. 8‚ 4/97). The manual provides step‑by‑step procedures for replacing internal components such as the temperature sensor (U100)‚ EEPROM (U10)‚ and input amplifier modules. Parts are identified by part numbers and can be ordered through Fluke’s parts catalog or authorized distributors. When ordering‚ verify the meter’s model and firmware version to ensure compatibility. After component replacement‚ perform a full calibration using the built‑in calibration routine or an external reference meter. Document all changes in the service log‚ noting the date‚ technician‚ and part numbers used. Regular maintenance schedules recommend inspecting probe contacts‚ cleaning with isopropyl alcohol‚ and checking the internal temperature sensor against a calibrated thermometer. Proper part replacement extends the meter’s service life and maintains its true‑RMS accuracy. For advanced diagnostics‚ refer to the troubleshooting section‚ which includes fault codes‚ diagnostic LEDs‚ and recommended corrective actions. Always keep the service manual in a secure location for future reference. The Fluke 87 Service Manual is available in PDF format on the Fluke website and can be downloaded after registering with an authorized Fluke account. If additional assistance is needed‚ contact Fluke technical support for guidance on part selection and repair procedures. Here:See manual for details!